Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Instrumentation ; (6): 84-87, 2014.
Article in Chinese | WPRIM | ID: wpr-259926

ABSTRACT

In order to meet the requirements of the multi-physiological signal measurement of the 3D-TV health assessment, try to find the suitable biological acquisition chips and design the hardware system which can detect different physiological signals in real time. The systems mainly uses ARM11/S3C6410 microcontroller to control the EEG/EOG acquisition chip RHA2116 and the ECG acquisition chip ADS1298, and then the microcontroller transfer the data collected by the chips to the PC software by the USB port which can display and save the experimental data in real time, then use the Matlab software for further processing of the data, finally make a final health assessment. In the meantime, for the different varieties in the different brain regions of watching 3D-TV, developed the special brain electrode placement and the experimental data processing methods, then effectively disposed the multi-signal data in the multilevel.


Subject(s)
Computer Simulation , Equipment Design , Microcomputers , Physiological Phenomena , Signal Processing, Computer-Assisted , Software
2.
Journal of Biomedical Engineering ; (6): 402-407, 2002.
Article in Chinese | WPRIM | ID: wpr-357016

ABSTRACT

The parallel-plate flow chamber (PPFC) with rectangular shape, of which the height is far smaller than its own length and width, is one of the main apparatus for in vitro studies of the mechanical behavior of the cells. Considering that the Reynolds numbers of flows in the usually used PPFCs are small, a perturbation solution of laminar pulsatile Casson fluid in the PPFC is presented using Reynolds number as perturbation parameter. Furthermore, the velocities and shear stresses in the PPFC are given. The numerical results demonstrate that under the same pressure gradient the shear stresses are almost identical between Casson fluid and Newtonian fluid, whereas under the same flux the shear stresses are obviously different between Casson fluid and Newtonian fluid. The results in this paper provide a theoretical way to determine the shear stresses in the parallel-plate flow chamber under pulsatile Casson fluid.


Subject(s)
Algorithms , In Vitro Techniques , Models, Cardiovascular , Pulsatile Flow , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL